Flat Roof Joist Span Table Uk
Flat roof with no permanent access and altitude not exceeding 100m 0 75 kn m udl 0 9 kn point load most areas exceeding 100m but not exceeding 200m excluding parts of scotland pennines north east england refer to bs 6399 3 1 kn m udl 0 9 kn point load.
Flat roof joist span table uk. Span tables for solid timber joists. This table uses commonly available uk regularised timber depths. Stocked at all branches click here to download c24 strength class pdf document. Notches are not to exceed 0 125 of the depth of the joist and are to be located between 0 07 and 0 25 of the span from the support.
Span is clear span between supports. Surveyors and structural engineers utilise data from tables below to help calculate the correct size strength and centres of roof timbers for the required spans and loadings. Tables 1 and 2 in this chapter are derived from the trada technology ltd. Maximum slop3 10 deg.
Joist breadth 47mm. Flat roof joists rafters purlin. Click here to download c16 span table leaflet c24 span table our premium grade of carcassing is c24 graded. For timber floors between homes.
For pitched roofs flat roofs and ceiling joists. Eurocode 5 span tables for solid timber members in floors ceilings and roofs for dwellings 3rd edition. The section sizes are based on regularised als or cls timber. Should refer to trada document span tables for solid timber members in floors ceilings and roofs excluding trussed rafter roofs for dwellings or ask your lbc surveyor for advice.
The floor joist span tables are based on the loadings given in the amended version of bs 6399 1 which is an imposed load of either a uniformly distributed load of 1 5 kn m or a concentrated load of 1 4 kn. Other span tables are based on. Supporting imposed load for access and repair only. At least 40mm bearing on supports.
Floor joists flat roof joists assumptions at 400mm centers supporting permanent load excluding self weight of joists up to 50kg m2. Span tables for flat roof joists to bs 5268 7 2 imposed loads of 0 75 kn m for maintenance and snow load are applicable where there is no permanent access no fixed ladder or staircase and most areas where the altitude does not exceed 100 metres refer to bs 6399 3 imposed loads of 1 kn m for maintenance and snow load are applicable where there is no permanent access no fixed ladder or staircase and most areas where the altitude exceeds 100 metres but does not exceed 200 metres. These span tables apply only to flat roof and roof with a slope of up to 10 degrees.